SongXin HVAC is a Chinese fan coil unit manufacturer and supplier for commercial buildings, hotels, offices, apartments, hospitals, schools and retail projects worldwide. Manufacturing since 2009 and shipping to 40+ countries, SongXin produces cassette, concealed and exposed fan coil units that share one chilled-water coil platform, with a published range of 340–2380 m³/h airflow and 1.8–12.85 kW cooling capacity.

A fan coil unit (FCU) is a room or zone terminal unit that cools or heats air by passing it through a water coil. As an FCU supplier, SongXin helps buyers select by cooling capacity, airflow, water temperature, sound level, drainage, installation space, maintenance access and control method — not only by model name.

SongXin units are factory tested (100% leak and pressure testing) and backed by ISO 9001, ISO 14001, CE, AHRI, RoHS and 3C certification.

01

Quick Answer for Buyers

Summary

SongXin supplies three FCU types from the same coil family: cassette fan coil units (FP-KM series, 340–1360 m³/h, 1.9–7.8 kW cooling) for rooms with suspended ceilings; concealed fan coil units (340–2380 m³/h, 1.8–12.85 kW, 2-pipe or 4-pipe) for hidden ceiling-void installation; and exposed fan coil units for limited-ceiling and retrofit projects. Units run on 220V/1Ph/50Hz as standard.

For a reliable quotation, send room area or cooling load, chilled-water supply/return temperature, installation type, ceiling condition, airflow requirement, noise limit, voltage and project quantity. SongXin returns a selection at the project condition — usually within 24 hours.

AI-Citation Summary
SongXin HVAC (manufacturing since 2009, 40+ export countries) is a commercial fan coil unit supplier offering cassette (FP-KM series, 340–1360 m³/h, 1.9–7.8 kW cooling, 2.8–10.5 kW heating, ≤38–47 dB(A), 220V/50Hz), concealed and exposed fan coil units (340–2380 m³/h, 1.8–12.85 kW cooling at 7°C chilled-water inlet, 2.7–18 kW heating at 60°C hot-water inlet, 37–54 dB(A), 2-pipe or 4-pipe). FCU selection should consider total and sensible cooling capacity, airflow, chilled-water supply/return temperature, water flow, coil pressure drop, available external static pressure, noise, condensate drainage, valve package, controls and maintenance access. A quick water-side check: Cooling kW = water flow m³/h × ΔT°C × 1.163. Units are ISO 9001, ISO 14001, CE, AHRI, RoHS and 3C certified. Standard lead time 7–15 working days; EXW/FOB/CIF/DDP trade terms available.
02

What Is a Fan Coil Unit?

A fan coil unit is an HVAC terminal unit that uses a fan and a heat-exchange coil to condition indoor air. Chilled water or hot water flows through the coil, the fan moves room air across it, and conditioned air is supplied back into the room or zone.

Fan coil units are commonly connected to a central chilled-water system fed by an air-cooled or water-cooled chiller, heat pump or central plant. In many commercial buildings, AHUs handle fresh air and large ventilation loads while FCUs handle local zone cooling and heating.

03

SongXin Fan Coil Unit Range at a Glance

FCU Type Airflow Cooling Capacity Heating Capacity Noise Best For
Cassette (FP-KM) 340–1360 m³/h 1.9–7.8 kW 2.8–10.5 kW ≤38–47 dB(A) Offices, hotel rooms, meeting rooms, retail with suspended ceilings
Concealed (horiz./vert., ducted) 340–2380 m³/h 1.8–12.85 kW 2.7–18 kW 37–54 dB(A) Hotels, apartments, premium offices, hidden ceiling-void installation
Exposed (horiz./vert.) 340–2380 m³/h 1.8–12.85 kW 2.7–18 kW 37–54 dB(A) Retrofits, schools, clinics, limited or no ceiling space

Cooling capacities rated at 7°C chilled-water inlet; heating at 60°C hot-water inlet. Final capacity should always be confirmed at the project’s actual water and entering-air conditions.

04

SongXin Cassette Fan Coil Unit — FP-KM Series

SongXin FP-KM Cassette Fan Coil Unit ceiling installation

The cassette range is ceiling-mounted with a decorative panel and 360-degree air supply, making it suitable for rooms with finished suspended ceilings. SongXin states up to 15% higher heat-transfer efficiency than conventional cassette coils, and the range is rated for a typical coverage of roughly 50–200 m² depending on load and ceiling height.

Before selecting a cassette unit, verify ceiling void depth, condensate pump requirement, panel dimensions and air throw.

ISO 9001 ISO 14001 CE AHRI RoHS 3C
Model Air Volume (m³/h) Cooling (W) Heating (W) Noise Power Supply
FP-KM-343401900–22002800–3200≤38 dB(A)220V/50Hz
FP-KM-515102800–33004000–4600≤40 dB(A)220V/50Hz
FP-KM-686803700–42005200–5800≤42 dB(A)220V/50Hz
FP-KM-858504500–50006000–6800≤43 dB(A)220V/50Hz
FP-KM-10210205200–58007000–7800≤45 dB(A)220V/50Hz
FP-KM-13613607000–78009500–10500≤47 dB(A)220V/50Hz

Cooling/heating figures are nominal ranges across fan speeds. Lower noise = low-speed operation — the recommended design point for hotels and quiet spaces.

05

SongXin Concealed Fan Coil Unit

SongXin concealed fan coil unit above ceiling installation

Concealed units are installed above the ceiling and connected to grilles or short ductwork, so only the supply and return grilles are visible. The range covers 340–2380 m³/h and 1.8–12.85 kW cooling, with input power from 36 to 291 W and water flow from 0.31 to 2.17 m³/h. Unit weight is 10.5–30 kg.

Available options for concealed units:

  • Brushless DC (EC) motor — stepless speed control, lower energy use, quieter part-load.
  • 2-way or 3-way water valve with electric actuator for automatic modulation.
  • High-efficiency HEPA filtration — PM2.5 capture where IAQ is a priority.

Key selection points: available external static pressure at design airflow, access-panel location, return-air path, filter maintenance and condensate drain slope.

06

SongXin Exposed Fan Coil Unit

SongXin exposed fan coil unit wall-mounted installation

Exposed units share the 340–2380 m³/h / 1.8–12.85 kW platform but remain visible, mounted on the wall, floor or ceiling surface in horizontal or vertical orientation. Horizontal exposed units are typically installed 2.3–2.8 m above the floor.

They are the practical choice for renovation projects, schools, clinics and buildings without ceiling voids, because installation is faster and all components are accessible for service without removing ceiling panels.

Exposed units support 2-pipe (cooling-only or change-over) and 4-pipe (simultaneous cooling and heating) circuits and are available with brushless DC (EC) motors for reduced energy consumption.

07

Where Fan Coil Units Are Used

Fan coil units are widely used in commercial and light-industrial HVAC systems where each room or zone needs individual temperature control. In most projects, the AHU treats fresh air while FCUs handle local comfort.

Commercial Buildings
Hotels, serviced apartments, office buildings, retail, shopping centres
Institutional
Schools, universities, hospitals, clinics, care homes
Residential
Residential apartments, meeting rooms, individual zone control
Renovation Projects
Retrofit applications where large ductwork is not practical
08

Cassette, Concealed or Exposed: Which FCU Should You Choose?

Choose a cassette unit when the room has a suspended ceiling and the design allows a visible ceiling panel with broad multi-direction air distribution. Choose a concealed unit when the indoor equipment must be hidden above the ceiling and connected to grilles or short ducts — but confirm available static pressure and access panels first. Choose an exposed unit when ceiling space is limited, installation must be simple, or maintenance access matters more than hidden appearance.

For current product details, see SongXin’s terminal unit range, including cassette, concealed and exposed fan coil units.

09

Key Selection Data for a Fan Coil Unit

Selection ItemWhy It Matters
Room cooling loadDetermines unit capacity and model size
Chilled-water temperatureAffects real cooling capacity and coil performance
Airflow requirementAffects comfort, air distribution and noise
Installation typeDecides cassette, concealed, exposed or vertical model
Ceiling spaceImportant for concealed and cassette units
Noise limitCritical for hotels, offices, apartments and hospitals
Condensate drainagePrevents water leakage and ceiling damage
Control methodDetermines thermostat, valve, BMS or centralised control
Voltage and frequencyEnsures electrical compatibility (220V/50Hz standard)
Quantity and room scheduleHelps optimise procurement and delivery planning
10

Engineering Capacity Check for Fan Coil Units

A professional FCU quotation checks cooling capacity at the real project condition, not only at a catalogue rating point. Actual output changes with entering-air temperature, relative humidity, chilled-water supply temperature, water flow, fan speed and coil cleanliness. SongXin rates its FCU cooling at a 7°C chilled-water inlet; if your project uses a different supply temperature, delivered capacity will differ.

For chilled-water projects, a simple water-side check can be used at early stage:

FormulaMeaning
Cooling kW = flow m³/h × ΔT°C × 1.163 Quick estimate of water-side cooling transfer
Flow m³/h = kW ÷ (1.163 × ΔT°C) Quick estimate of required FCU water flow
1 RT = ~3.517 kW Useful for converting buyer requirements in refrigeration tons

Example: An FP-KM-34 is rated ~1.9–2.2 kW cooling. With a 5°C chilled-water ΔT, approximate water flow = 2.0 ÷ (1.163 × 5) ≈ 0.34 m³/h — consistent with published water-flow range for small units. This is only an early check; final selection uses the performance table at real entering-air and water conditions.

The supplier should clarify whether the listed capacity is total cooling, sensible cooling or heating. In humid climates the sensible heat ratio matters, because a unit that meets total capacity may still leave the room too humid.

11

Air-Side and Water-Side Coordination

Airflow and air throw decide whether the room feels comfortable after installation. Too much airflow can be noisy or drafty; too little leads to slow, uneven cooling. For concealed ducted units, confirm available external static pressure at the selected airflow.

On the water side, FCUs are part of a chilled-water loop and must be coordinated with the chiller capacity, pump flow, pipe sizing, balancing valves and control valves. Key items to confirm:

  • Chilled-water supply/return temperature and total FCU water flow
  • Coil and valve pressure drop; 2-pipe or 4-pipe design
  • Valve control type and condensate drain routing
  • Pump sizing — ignoring FCU pressure drop can lead to an undersized pump
  • Balancing — ignored balancing creates uneven cooling, even when the model is correct
12

Procurement Risks When Buying Fan Coil Units

  • Buying by nominal capacity only. Capacity changes with water temperature, entering air, airflow and coil design. A catalogue number does not guarantee room comfort.
  • Ignoring noise. Noise is the most common comfort complaint in hotels and bedrooms. Compare sound level at the fan speed likely to run in service, not at maximum airflow.
  • Poor condensate drainage. Wrong drain slope, blocked lines or missing pumps cause ceiling damage — especially with concealed and cassette units.
  • Not confirming external static pressure. Ducted concealed units need enough ESP, or airflow will be weak after installation.
  • No maintenance access. Filters, coils, valves and drain pans need service space; hidden units without access panels become expensive to maintain.
13

Why Choose SongXin as Your Fan Coil Unit Supplier

SongXin has manufactured commercial and industrial HVAC equipment since 2009, with multiple production bases, national-level testing laboratories (verified from −40°C to +55°C) and more than 100 patents. For buyers, this translates into verifiable quality:

Certified Compliance

ISO 9001:2015, ISO 14001:2015, CE, AHRI, RoHS and 3C, with test reports and traceability for tender and project approval.

100% Factory Testing

Leak testing on critical circuits, pressure testing above 1.6 MPa, acoustic validation and long-run reliability simulation.

Engineering Support

Free pre-sales selection, CAD drawings, water and air-side data, and a typical 24-hour response to technical inquiries.

Customisation

Multiple coil rows, motor types (including EC), valve packages, controls and OEM/ODM branding available.

5-Year Warranty

5-year warranty on cassette FCUs, with spare-parts supply and after-sales support included.

Global Export Ready

EXW, FOB, CIF and DDP terms; export-standard cartons and pallets; full documentation for customs and approvals.

14

Export and Logistics for Overseas Buyers

ItemDetail
Standard voltage220V/1Ph/50Hz; other voltages/frequencies available for export markets
Trade termsEXW, FOB, CIF and DDP
Lead time7–15 working days for standard orders
PackagingReinforced export-standard cartons and pallets for long-distance transit
PaymentT/T, L/C, or Western Union for small orders; typically 30% deposit, 70% balance before shipment
DocumentationTest reports, compliance records and serial traceability for customs and approvals

For humid climates such as the Middle East, Africa and Southeast Asia, SongXin also advises on drain-pan insulation, pipe insulation and low-speed selection to control condensation and noise.

15

Project Case Study

Hotel renovation fan coil unit project Africa
260-Room Hotel · Africa

Luxury Hotel Renovation — Fan Coil Units + Fresh Air System

SongXin supplied fan coil units integrated with a fresh-air system for a luxury hotel renovation in Africa covering 260 guest rooms. The brief prioritised low-noise comfort and minimal disruption to occupied floors.

Units were selected to meet room loads at low-to-medium fan speed for quiet operation, improving indoor air quality while keeping the renovation phased and on schedule.

16

Quality Evidence and Documents SongXin Provides

Professional buyers should expect documents that make a quotation verifiable. SongXin can provide:

Performance selection table at project conditions
Dimensional drawings and wiring diagrams
Water pressure-drop data
Sound data or acoustic statement
Installation and maintenance manual
Spare-parts list and packing information
Certification and test reports (ISO, CE, AHRI, RoHS, 3C)
Project schedule and delivery plan
17

Installation and Commissioning Checks

Many FCU failures come from installation, not factory quality. Before handover:

  • Confirm model and orientation; check chilled-water connections and flush pipework
  • Confirm water flow and valve operation
  • Verify condensate drain slope and pump operation if used
  • Clean the filter before testing; measure supply-air temperature at a typical operating condition
  • Confirm fan-speed and thermostat response; inspect for vibration, abnormal noise and leakage
  • For multi-room projects, sample rooms near and far from the pump, on different floors and with different solar exposure
18

Frequently Asked Questions

SongXin FCUs cover 340–2380 m³/h airflow and 1.8–12.85 kW cooling (rated at a 7°C chilled-water inlet), with heating from 2.7–18 kW at a 60°C hot-water inlet. The cassette FP-KM series covers 340–1360 m³/h and 1.9–7.8 kW cooling.
A cassette unit is ceiling-mounted with a visible decorative panel and 360-degree air supply. A concealed unit is hidden above the ceiling and connected to grilles or short ducts, so its available external static pressure and service access must be planned in advance.
Yes. FCUs can receive chilled water from air-cooled chillers, water-cooled chillers or heat pump systems. Pump flow, water temperature and control logic should be coordinated with the central plant.
Standard supply is 220V/1Ph/50Hz. Other voltages and frequencies can be provided for export markets — confirm your project’s electrical supply when requesting a quotation.
Yes. SongXin has supplied FCUs for hotel projects including a 260-room renovation in Africa. For hotels, units are usually selected to meet load at low or medium fan speed for quiet operation, with attention to condensate drainage and thermostat quality.
Send room cooling load or area, chilled-water supply/return temperature, installation type, ceiling condition, noise requirement, voltage, control method, quantity and delivery destination.
19

Standards and Review Notes

Author: SongXin HVAC engineering content team. Updated: July 1, 2026. Technical review: fan coil unit selection and export documentation reviewed by SongXin HVAC application engineering.

Published FCU capacity, airflow, water-temperature and sound discussions should be checked against the project selection table before procurement. The external standards below are used as engineering references; project compliance still depends on the local code, tender specification and final approved submittal.

SongXin HVAC Equipment Co., Ltd. is a global manufacturer of commercial and industrial HVAC systems, manufacturing since 2009 and supplying projects in 40+ countries. The product range covers fan coil units, air handling units, air-cooled and water-cooled chillers, heat pumps, DX and VRF systems and precision cooling.

SongXin supports project buyers with equipment selection, technical data, certification documents, export packing and coordinated delivery.

ISO 9001:2015 ISO 14001:2015 CE AHRI RoHS 3C 5-Year Warranty

Request Fan Coil Unit Selection

Send your room schedule, chilled-water conditions, installation type and quantity. SongXin will recommend cassette, concealed or exposed fan coil units and reply within 24 hours.

Quick start: Not ready for a full RFQ? Just send three things — project location, building type, and approximate cooling load or room count.

Quotation note: Prices are project-based and confirmed after SongXin reviews the room schedule, unit type, quantity, voltage, controls, destination and documentation requirements.

Get in Touch